Continuous insulation extends downward from the top of the slab and along the entire perimeter and completely covers the entire area under the slab.
Slab edge insulation at garage door.
Slice inch slits through the insulation above the retention clips and attach the front of the retention clips to the back pieces to secure the insulation panels.
The f factors for slab on grade floors are defined in standard 90 1.
2 thick t g xps comes in 2 wide sections by a number of different lengths 8 10 12 and on edge at the door would deliver r10 down to about the same depth as your interior insulation.
This edge thing is a big deal the thermal bridging that occurs if you don t do it costs you more than half the thermal resistance of the whole deal.
So neither bat insulation or spray foam insulation is going to work well on the garage door.
The easiest is a slab supported by good dirt and a new one at that.
You make the assembly out of three pieces a footing a stem wall and the flat plate slab part.
Even if you find products designed for application against a garage door the constant movement of the garage door will eventually cause them to flake pull apart and fail which means that you re looking at insulating your door again and again.
The space above is conditioned slabis onefoot or less below grade summary slab is one foot or less below grade r 10 insulation required extending 2 feet below grade for climate zones 4 and 5 4 feet below grade for climate zone 6.
Below grade to have r 10 vertical insulation at the slab perimeter extending downward from the top of the slab to a depth of at least 2 ft.
The slab edge system in the link is only r7.
Push insulation flat against door and feel for retention clips.
If the slab has hydronic tubing the minimum r value of this insulation increases to r 15.
Slab insulation is required when.
Then you insulate it under it and on the inside of the perimeter making sure you uncouple the plate from the stem wall at its edge.